9.2 PERIODICAL MAINTENANCE
- Often clean the keypad, the mouse and the shelf where the are positioned
- Clean the filters of the fan, on the control cabinet
- Take out the sawdust deposit on the guides on the rolls of the plan and on the intake cover
- Check that the condensate that deposit in the clear pan of the FILTER-REDUCER GROUP
(F-R) has not reached the maximum limit. For emptying, turn the breather 90° in clockwise
direction
- Lubricate every 200 hours of the following parts of the machine using NLGI 2 or higher (es.
KLUBER ISOFLEX TOPAS52, MOBILTEMP SHC100, APIGL-1).
1) Use the greaser
2) Open lateral door
3) Lubricate the head using the connector shown in the
picture