PULL-TO-OPEN LIMIT SETTING
(Open gate to inside of property)
Single Gate Installations
Step 1
Make sure the gate is in the fully open position.
Ensure power switch is in the ON position.
Step 2
Verify Block 2, DIP Switch #1 is in OFF position.
Press the cycle button on circuit board and the
gate will begin to close. Stop the gate using the
cycle button when the desired limit has been
reached.
Step 3
Press and hold the “SET LIMIT” button until one
audible beep is heard to acquire the closed limit
setting. The STATUS light will turn on
immediately upon pressing the SET LIMIT
button. The STATUS light will turn off and an
audible beep will verify the closed limit is now
set.
Step 4
Press cycle button on circuit board to return the
gate to the fully open position.
Step 5
Again, using the cycle button close the gate to
verify it meets the desired location. If the gate did
NOT reach the desired closed limit, proceed to
step 6.
Step 6
CLEARING THE CLOSED LIMIT SETTING:
a) Return the gate to the fully open position.
b) Press and hold the SET LIMIT button until two
audible beeps are heard.
c) Two audible beeps will verify the closed limit
setting is now cleared.
Repeat steps 1 5 to program the gates “closed
limit setting”.
WARNING: Do not use hand held
transmitters to program primary
and secondary limits. Only the
cycle button should be used until
final set up is complete to avoid
damage to actuators and voiding
warranty.
***Dip switch number 6 dictates which
gate is being affected by the set limit
button, whether setting or clearing the
limit. If dip switch 6 is in the up position,
it will set or clear the limit for the
secondary operator. If it’s in the down
position it will set or clear the limit for
the primary operator.***