3
9926814 R08 - 2015-2016 RZR 900 2016 RZR S 1000 Service
Manual
© Copyright Polaris Industries Inc.
3.85
24. MECHANICAL TENSIONER ONLY:
• Retract the plunger all the way in and install into the
cylinder.
• Install the two mounting bolts. Torque fasteners to
specification.
TORQUE
Tensioner Mounting Bolts:
7 ft-lb (10 Nm)
• Install the plunger bolt. Torque fastener to
specification.
TORQUE
Plunger Bolt:
15 ft-lb (20 Nm)
25. Rotate crankshaft through two revolutions and verify
camshaft timing is correct.
ENGINE / COOLING SYSTEM