Starter Solenoid Bench Test
Test the start solenoid by powering the solenoid using
battery voltage for a maximum of 5 seconds. With the
solenoid energized, resistance should read about 0 - 0.5
ohms between terminals (A) and (B). If resistance
measurement is out of specification, replace the starter
solenoid
Starter Solenoid Operation
To energize the Starter Solenoid the following must
occur:
The brake must be applied to provide a ground path
via the orange wire.
The key switch must be turned to the “start” position to
provide 12V power via the Green / White wire.
Once the pull-in coil is energized, the solenoid
provides a current path for 12V power to reach the
starter motor.
NOTE
See “ELECTRICAL SYSTEM BREAKOUTS: Starter-
Interlock” provided in this chapter for starter
solenoid operation.
TORQUE
Starter Solenoid Cable Fasteners:
35 in-lb (4 Nm)
ELECTRICAL

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polaris RZR 900 2015 and is the answer not in the manual?

Polaris RZR 900 2015 Specifications

General IconGeneral
BrandPolaris
ModelRZR 900 2015
CategoryOffroad Vehicle
LanguageEnglish

Related product manuals