TROUBLESHOOTING
VORTEX EF2211/EF2210 Reference Manual 42 Technical Support: 800.932.2774
— D/A, amplifier, loudspeaker, microphone, and A/D — to cancel acoustic echoes.  
If you overdrive the loudspeaker or insert a dynamics processor before the echo can-
celler, the acoustic reflections picked up by the microphone do not match the signal 
fed to the loudspeaker.  They are distorted copies of this signal.  The EF2211/EF2210 
cannot effectively cancel this distorted signal.
If you suspect the loudspeaker is introducing nonlinearities into the room acoustic 
path, take these steps to minimize its influence on the echo canceller.
• Keep the loudspeaker’s volume level at less than three-eighths of full scale.  If 
higher volume is required, the EF2211/EF2210 should operate effectively at vol-
ume settings of up to 50 percent of full scale.  At more than 50 percent, most 
audio systems and loudspeakers introduce significant nonlinearities.  The 
EF2211/EF2210 may not adapt under these conditions, and echoes may be heard.
• If the loudspeaker has a bass control, lower it.  Excessive bass can cause a boomy 
effect that is nonlinear.  In addition, excessive bass may cause substantial 
mechanical coupling to the microphone through vibrations induced in the hous-
ings and support structures.
• Increase the separation distance between microphones and the loudspeaker.  The 
EF2211/EF2210 handles up to 10 dB of room gain between the loudspeaker and 
the microphone.  You may be exceeding this limit if the loudspeaker is pointed 
directly at the microphones or if the loudspeaker volume is excessive (loud-
speaker placement is not critical, but it should not be pointed directly at the 
microphones).
C
ONTACTING
 T
ECHNICAL
 S
UPPORT
If these troubleshooting guidelines don’t resolve the problem you are experiencing 
with the EF2211/EF2210, please check our web site (http://www.polycom.com) for 
the most current technical support information (go to Products & Services, then to 
Voice Products, then to Installed Voice Systems).  If you have further questions, 
please contact us at:
Applications Engineering
Polycom Installed Voice Business Group
9040 Roswell Road
Atlanta, GA  30350
Phone: (800) 932-2774
Email: vortex@polycom.com
Before contacting us, please review the warranty and repair policy on page 56.