CONNECTOR PINOUTS
VORTEX EF2211/EF2210 Reference Manual 54 Technical Support: 800.932.2774
C
ONNECTING
 U
NBALANCED
 RCA 
TO
 B
ALANCED
 T
ERMINAL
 B
LOCK
1. Connect RCA Tip to terminal block pin 1.
2. Connect RCA Ring to terminal block pin 2.
3. Connect terminal block pin 3 to Shield, and leave Shield floating on RCA end.
M
AKING
 
AN
 EF B
US
 T
ERMINATOR
Instructions To make a terminator (for use when connecting EF2280s), use an RJ45 connector.  
Connect pin 3 to pin 6 with an 110 Ohm resistor.  A terminator is not required for the 
EF2211/EF2210 as it is built in.
Figure 30. Cable construction for connecting unbalanced RCA to balanced 3-conductor terminal block.
Red
Black
Red
Black
Shield
Tip
Ring
RCA Male
3.5 mm Terminal Block 
Connector
2
1
3
+
-
Caution!  Do NOT connect the shield at both ends.
Caution!  On the EF2211/EF2210, the terminal block pin 3 
is connected to chassis ground.  Under no cir-
cumstances should pin 3 be connected to pin 1 
or to pin 2.  Doing so will add noise to the audio 
signal.
Figure 31. The terminator
12345678
110 Ω