OWNER’S MANUAL
Problem Cause Solution
1. Motor
p
doesn’t start,
or kicks on and off
2. No or slow water
flow from the
Return Fitting
6
3. Pump is not cleaning
the pool properly e.g.
cloudy/green water
4. Water leakage at
A. Plug the GFCI Power Cord Set
j
to a 3-wire grounded power outlet. Then press
the RESET button to restart it.
B. Reset your circuit breaker on the electrical panel. If problem persists, have the circuit
checked by a qualified electrician.
C. Check and make sure the line voltage is between 105V and 125V.
A. Fill the pool to the FILL LINE. The Suction Fitting
2
must be at least 4” under water.
B. Check for obstructions at the Filter Cartridge
a
, Suction Fitting
2
or Return Fitting
6
.
C. Clean or replace the Cartridge following the steps of FILTER CARTRIDGE USE & CARE (p. 12).
D. Refer to pump servicing instructions to clean dirt.
A. Not plugged in
A. Low pool water level
B. Clogged inlet/outlet
D. Motor Rotor block by dirt
A. Inadequate chlorine level
C. The Filter Cartridge
a
is too dirty
A. Maintain the chlorine level between 1.0 and 1.6 ppm.
B. Maintain the pH level between 7.3 and 7.8
C. Clean or replace the Cartridge following the steps of FILTER CARTRIDGE USE & CARE (p. 12).
D. Inspect the Cartridge for holes or tears. If it’s visibly damaged, replace it with a new one.
E. Check for obstructions at the Filter Cartridge
a
, Suction Fitting
2
or Return Fitting
6
.
F. Have your pool water sample tested by a pool supplies store. You may need to add
other chemicals since water quality varies in different localities.
G. Chemicals are essential to keep the pool water clean. Clean the pool and filter more often.
A. Check that the Hose Clamps
q
are properly secured over both the Hoses
9
and their
O-rings
k
; adjust and retighten if necessary. Also, check the Hoses for cracks or holes and
replace as needed.
B. Check the Vent Screw O-Ring
r
for damage and replace as needed. Also retighten the Screw.
B. Inadequate pH level
C. The Filter Cartridge
a
is too dirty
D. The Filter Cartridge
a
is damaged
E. Water flow is slow
F. Other chemicals required
G. Pool water is too dirty
A.
Suction
2
/ Return
6
fittings
or Hose
9
connection points
B. Vent Screw
e
C. Check the Canister Gasket
u
for damage and replace as needed. Also retighten the Seal Top.
C. Seal Top
t
D1. Check the Canister Gasket
u
for damage and replace as needed.
D2. Check that the Gasket sits correctly in the groove at the bottom of the Canister
i
.
D. Pump Body
d
B. GFCI Power Cord Set
j
and/or circuit breaker tripped
C. Low voltage
TROUBLESHOOTING GUIDE