Troubleshooting
After a correct installation and connection, your Polytropic heat pump doesn’t
work correctly?
This table can help you.
First, please verify that:
• Heat pump is correctly connected to power supply and well controlled by
filtration pump.
• Heat pump is correctly connected by water tubes (hydraulic circuit) to
swimming pool.
• Heat pump is correctly placed (distance to surrounding elements)
Fault Probable cause Checking Answer
Relay is not connected
to “1” and “5”
Verify connections
Connect or Install
relay
Phase error detector
stops the heat pump
(tri-phase heat pump)
Invert two phases and check again.
No digital display
ignition
LP pressure controller
cut off
It starts few minutes later
Wait till water
temperature is higher
than 15°C
Ignition of fan is
OK, but heat pump
does not work
Defrost mode
Check
button setting.
Has to be set to « 7 »
Once the ambient
temperature is >7 the
heat pump will start
working
Heat pump works
correctly but it
stops few minutes
after starting
Gas charge problem
Check if the pressure
gauge indicates 5 to 10
bars when heat pump is
stopped
Contact your seller
This heat pump is too
small for the pool and/or
season
Check with Polytropic
software
www.polytropic.fr
“aquavariation” menu
Contact your seller
By-pass needs
adjustments
Check by-pass setting
Please see water
setting chapter of this
handbook
Heat pump works
but pool water
temperature does
not increase (or too
slow)
No cover present
Equip your swimming pool
with a cover
Install a solar cover