Current Limit
Motor Type
Advanced programming should only be undertaken by engineers with the required training
Caution - Damage to the curtain / equipment may occur if these settings are incorrect
This menu is used to set the stall current of the motor. If the Motor Type is set to “Gravity F /Safe” a stall will result in a
“Current Limit” error being displayed.
Press the middle button to store
Options - Stall Open or Gravity F/Safe
Press the Up or Down button to select the desired current
This menu selects the motor type being used.
Gravity F/Safe (Gravity Failsafe) is the ASB motor and uses the upper limit on the motor to stop the curtain
Press the middle button to store
Range - 1.0A - 7.0A
Press the Up or Down button to select “Stall Open” or “Gravity F/Safe”
Stall Open requires a physical stop in the upper position to stall the curtain. The current limit must be set in the current limit
menu to ensure the curtain is not damaged during stalling.
Press the middle button to enter menu
Press the middle button to enter menu
Advanced Programming of P1000 - Expert Mode - Menu Setting