2.3.5Maxmainscurrent
Thefigure2.3.8showstheMaxmainscurrentscreen. The"+"and"-"buttonschangethevalueofthemaxmainscurrent
inputintherangefrom15to32A (8to16A forK3,K3I,K2andK2I).Maximummainscurrentlimitsetthermsvalueat
whichaC-Typecurrentbreakerwilltrip-off.
figure2.3.8
2.3.6CliplimiterCH1-CH2
Enablethisfunctiontopreventthedistortionduetoexcessiveamplitudeofoutput .signal Youcanenable/disableitby
pushingtheon/offbutton.
.
CAUTION:Thereistheriskofdamagetotheloudspeakers,ifClipLimitersaredeactivated. Youshouldnot
deactivateClipLimitersunlesstheirfunctionistakenoverbyexternaldevices,suchasdigitalsystemcontrollers.
Insuchcasesitismandatory,toproperlyadjustparametersintheexternaldevice
16
2.3.3Inputselect
Youcanchooseamongthreedifferentinputmodes(ifavailable): Analog,Digital AS3*withorwithoutDSP processingand
Ethernet**. Theupanddownbuttonschangetheselection;the"sel"buttonlockstheselectedoption.
* AvailableonlywithoptionalDSP board
** AvailableonlywithoptionalKAESOPboard
2.3.4Maxoutputvoltage
Thefigure2.3.7showstheMaxoutputvoltagescreen. YoucanchoosetosetCH1,CH2orbothbypushing"C1+2"
button. The"+"and"-"buttonschangethevalueofthemaxoutputpeakvoltage. Therangesavailableareshowedinthe
tablebelow
figure2.3.7
back
-
+
Maxmainscurrent
22Arms
fast
back
-
+
C1+2
Vpeak
102
Maxoutputvoltage
102
MODEL
K6 K8 K10
40to20040to16940to153
Valuesofpeakvoltage(V)
K4
40to125
K20
40to225
K3
40to165
K2
40to140