E
Digital Audio Amplifier
for Professional Applications
User Manual
v1.2 (24/11/2004)
Question and Answer IconNeed help?

Do you have a question about the powersoft DIGAM K series and is the answer not in the manual?

powersoft DIGAM K series Specifications

General IconGeneral
Amplifier ClassClass D
Number of Channels2
THD<0.5% from 0.1W to full power
Input Sensitivity1.4 Vrms
Damping Factor>500
Cooling SystemForced air
ProtectionThermal, short circuit, DC, overload
AC Power100-240 V, 50/60 Hz
Dimensions483 mm (19 in) x 88 mm (3.46 in)

Summary

Important Safety Instructions

Safety Rules and Precautions

Installation and Operation

Setup and Settings

Front Panel Overview

Introduction to the front panel controls, buttons, and graphic LCD display.

Main Screen and LED Indicators

Explanation of the primary display screen status and LED indicators.

Main Menu Navigation

How to navigate through the amplifier's main menu options using buttons.

Output Attenuation Control

Adjusting the signal level output attenuation for channels in 1dB steps.

Gain and Sensitivity Settings

Configuring amplifier gain and input sensitivity levels for optimal performance.

Input Selection

Choosing between Analog and Ethernet input sources for the amplifier.

Maximum Output Voltage Configuration

Setting the peak output voltage limit for channels to protect connected equipment.

Maximum Mains Current Setting

Adjusting the maximum allowable mains current draw to protect the power source.

Clip Limiter Functionality

Enabling/disabling the clip limiter to prevent output distortion and speaker damage.

Gate Functionality

Muting channels based on input signal amplitude thresholds to reduce noise.

Temperature Monitoring

Displaying historical temperature data and current internal temperature readings.

Mains Voltage and Current Meters

Monitoring the incoming mains voltage and current of the power supply.

Protection