EasyManua.ls Logo

PPA Jet Flex - Analog Limit Swtich Installation

PPA Jet Flex
9 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 13
8
th
step: Provide shims to ensure the rack alignment if the gate leaf is warped.
There are cases where the rack must extend the leaf length. In this case, provide an
angle bracket so no tooth is skipped when starting the operator.
9
th
step: After xing the rack, x the operator on the oor or concrete base, and
tighten the screws.
ANALOG LIMIT SWITCH INSTALLATION
1
st
step: With the gate closed, place the magnet support on the rack facing the
operator’s REED. This magnet will act as a closing limit switch.
ANGLE BRACKET
FOR THE FINAL FASTENING,
TIGHTEN THE 2 ¼” x 2 ½” S
SCREWS
FOR THE FINAL FASTENING,
TIGHTEN THE 2 ¼” x 2 ½” S
SCREWS
MAGNET BRACKET
REED SUPPORT
TOP VIEW
GATE CLOSING
MAGNET
BRACKET
RACK