4225V100-UK 17
**Power output limitations - 4225C
Power limitations when using buffered voltage output (4225C only)
600500400300200100 700 800 900
400
300
200
100
500
Sensor supply output power
Digital output power
Correct
operating range
Overpower
condition
mW
560 mW
mW
Power limitations when using current output with 10 mA maximum output (4225C only)
600500400300200100 700 800 900
400
300
200
100
500
Sensor supply output power
Digital output power
Correct
operating range
Overpower
condition
mW
460 mW
mW
Power limitations when using current output with 20 mA maximum output (4225C only)
600500400300200100 700 800 900
400
300
200
100
500
Sensor supply output power
Digital output power
Correct
operating range
Overpower
condition
mW
260 mW
mW