EasyManuals Logo

PR Lighting PR-8110 User Manual

PR Lighting PR-8110
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
11/16
PRODUCT CLEANING
To ensure the reliability of the fixture it should be kept clean. It is recommended that the fans should be cleaned every 15
days. The lens should also be regularly cleaned to maintain an optimum light output.
Do NOT use any type of solvent
containing chemical elements.
Cleaning intervals depends on the environment in which the fixture operates and use frequency. A soft cloth and typical
glass cleaning products should be used in cleaning the fixtures. It is recommended to clean the external optical system at
least once every 20 days.
Do not use any organic solvent, e.g. alcohol, to clean the housing of the apparatus to avoid damages
TROUBLE SHOOTING
PROBLEM ACTION
The fixture can not start
¾ Check if the fuse on the power socket is broken or not .
¾ Check the status of the fuse
The lamp works normal but the fixture
doesn’t respond to the controller
¾ Check if the fixture’s start address is set properly
¾ Check if XLR signal cable is broken or not
The fixture only functions intermittently
¾ Make sure the fans work normally and if dirt blocks fans and fan
screens.
The beam appears dim and brightness
decreases apparently
¾ Check if the lamps reach the end of their lives
¾ Check if external and internal optical systems are clean or not.
TECHNICAL DATA
LIGHT SOURCE:
OSRAM OSLON 3W(12R+12G+12B)
VOLTAGES:
90~264VAC 50/60HZ
POWER CONSUMPTION:
140W@220V
COLOR SYSTEM:
RGB color mixing system
2700K~10000K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the PR Lighting PR-8110 and is the answer not in the manual?

PR Lighting PR-8110 Specifications

General IconGeneral
BrandPR Lighting
ModelPR-8110
CategoryDJ Equipment
LanguageEnglish

Related product manuals