13
filling your bottle and have removed it from the fill chamber, return the shelf to the storage
position.
Activation Controls
Once the bottle is full, re-apply the cap. New caps for crown neck bottles should be available
to the customer at no extra charge. Remove the bottle.
For double dispensers, two bottles may be filled at the same time.
Adjusting Bottle Fill Capacity
To adjust fill capacity auto shutoff, first remove dispenser top cover. Locate & put in place a 5
Gal bottle in dispensing compartment, start flow & time filling of the bottle to approximately
90% (Start of the neck of the bottle) as shown in bottle fill illustration. Adjust timer knob to
approximate time (each number indicates 1-minute increments). Empty & retest bottle fill &
timer, adjust to reach appropriate fill level. Once achieved, reinstall top cover. Operation of
timer function is to prevent start button being pushed & unit left to run continuously. For small
bottles, start fill & stop when desired fill level reached.