Diagram 5.2 - Eddy Current Magnet (serial code A998)
4. If the resistance measures significantly less than 90 or significantly more than 110 .
THEN... OTHERWISE...
Replace the magnet as described Reconnect the magnet wires, then
in Procedure 7.13. continue with the next step.
5. Re-install the rear cover as described in Procedure 7.1, then check the operation of the unit
as described in Section Four.
6. Set the on/off switch in the “on” position. Thoroughly test all lift related functions per Section
Four.
7. Set the on/off switch in the “off” position, replace the front cover per Procedure 7.1.