7. Set the on/off switch in the “off” position. Do not exit the diagnostic program in the normal
manner. Exiting the diagnostic program will cause the lift to self center and invalidate the lift
calibration just performed.
8. Raise the ramp assembly to a convenient height and slide the lift yoke into the ramp
assembly. Hand tighten the four lift yoke mounting screws and then torque them to
240 in/lbs.
9. Set the on/off switch in the “on” position. Thoroughly test all lift related functions per Section
Four.
10. Set the on/off switch in the “off” position, replace the front cover per Procedure 7.1.