9.45, 9.45i Treadmill
Page 25
3. Plug the power cord into the wall outlet, then turn on the treadmill with the ON/OFF switch.
4. If necessary use conductive spray (Precor part number 37364-101) to ensure good contact
between the chest strap transmitter and the user, put on the heart rate chest strap
transmitter.Enter the diagnostics program per Procedure 2.1 or 2.2. Proceed to the heart
rate test portion of the diagnostics program. HArt will be displayed in the right display
window when the heart rate routine is accessed.
5. If the HEART RATE indicator blinks with your heart beat and the heart rate information
displayed is correct...
THEN... OTHERWISE...
The Smart Rate system is operating Continue with the next step.
correctly. There is no need to continue
with this procedure.
6. Re-adjust the fit of the chest strap. If the HEART RATE indicator still does not blink as
described in Step 4. If the chest strap transmitter has a replaceable battery, replace the
battery. If the HEART RATE indicator still does not blink as described in Step 5...
THEN... OTHERWISE...
Continue with the next step. The Smart Rate system is operating
correctly. There is no need to continue
with this procedure.
7. Hold the Heart Rate Test Transmitter (Precor part number 20045-101) near the display
housing. If the HEART RATE indicator on the electronic console blinks with the LED on the
Smart Rate Test Generator...
THEN... OTHERWISE...
The chest strap assembly is bad. The heart rate receiver assembly is
Wear a new chest strap assembly bad. Replace the heart rate receiver as
when you use the Smart Rate described in Procedure 5.4 of the
System. Residential Treadmill Service Manual.
8. Press ENTER to return to the User ID.