EasyManua.ls Logo

Precor 905e - Page 25

Precor 905e
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
905E, 9.1, 9.10 Treadmills
Page 25
Note:
The software version number is labeled on the PROM (U3).
10. Position the upper PCA at its mounting location, then replace the screws that secure the
upper PCA to the electronics housing assembly.
11. Carefully connect the keypad to the upper PCA.
12. Turn the electronics housing assembly so that the display label is facing up. Carefully move
the electronics housing assembly until it can rest on the right handrail.
Diagram 6.4 Partial Layout of the Upper PCA
13. Remove the ground lead of the wrist strap from the treadmill frame, then remove the wrist
strap from your arm.
14. Check the operation of the treadmill as described in Section Three of this appendix.
15. Stop the treadmill by placing the magnetic safety key in the OFF position, then unplug the
power cord from the wall outlet.
16. If the treadmill operates correctly . . .
THEN . . . OTHERWISE . . .
Skip to Step 31. Continue with the next step.
17. If the electronic console displays incorrect data or if all of the display area is blank . . .
DS1 DS2 DS3 DS4 DS5
U1
U3
J2
J1

Other manuals for Precor 905e