INSTALLATIoN
INSTALLATION OF TWO HEATING CIRCUIT
CONTROLLED BY ROOM THERMOSTAT ACV 15
AND AM3-11 MODULE

This is a simple way to control two heating circuits (radiators
or floor heating).
You can adjust those two circuits depending on the outside
temperature.
This is the ideal configuration for floor heating with additional
heating provided by radiators.
The floor heating temperature is adjusted on a first temperature
diagram, while the radiator loop follows a second temperature
diagram, if needed with a booster function.
AF120
ACV 15
MCBA
RAM
NTC12K
AM3 - 11
 Code Description
10800018 Room thermostat ACV 15
10800095
AM3-11 module :
Controls the second heating circuit - communicates directly with the MCBA
537D3040
Contact sensor 12kΩ
To be mounted on the outlet of controlled circuit
10510900
Contact thermostat RAM 5109 :
Required to protect all floor heating circuits
10510100 Outside temperature sensor 12kΩ — AF120
10800077
Collector 2 circuits DN20 :
With bypass, connecting tubes and integrated wall brackets
10800097
High temperature kit DN20
Including: one circulation pump, two isolating valves, check valve, two thermometers
10800096
Low temperature kit DN20
Including: one circulation pump, two isolating valves, check valve, two thermometers, the
4-way valve with integrated bypass.
10800019
Servomotor SQK 349 :
Electromechanical servomotor SQK 349 for the three-way valve included in low tempera-
ture kit
(opening times : 150 seconds)