EasyManua.ls Logo

Primex BC100 - No Network Mode

Default Icon
30 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No Network mode
No Network mode is required when an Ethernet or Wi-Fi network is not available during installation. During this mode, the Smart-Sync
Bridge does not connect to the facility's network to check-in to OneVue or obtain UTC time from a Network Server.
During No Network mode, the Smart-Sync Bridge is required to be configured with local time, which allows Smart-Sync Clocks to
receive and set their time to the local time configured in the bridge. Local time is configured using the Primex Device Configuration
software.
When the facility's network is available, the device must be set back to Normal (Bton) mode to allow its network connection to the
facility's Ethernet or Wi-Fi network.
How to set a Smart-Sync Bridge to No Network mode
WARNING:
Use of AC-power is required when operating in No Network mode. When operating on only continuous battery backup-
power, the device's estimated battery life is only up to one (1) day.
1.
Press and Hold the button for 3 seconds.
2.
Verify NoNt is shown on the LCD display, which indicates it's in No Network mode.
Next, configure the bridge with the computer's local time.
How to configure the bridge with local time
The bridge sets its internal time to your computer's local time. If you want to bridge to receive time from a different time zone, change
your computer's time zone before beginning this procedure.
WARNING:
Do not remove power from the bridge during this procedure - it must remain powered on at all times.
1.
Download and install the Primex Device Configuration software.
Installation requires administrator permission and a computer with Windows® 7 or 10 (32 and 64-bit). If you do not have
administrator permission, contact your IT department to install the software.
To download the software from your OneVue account, go to Help > Devices > Primex Device Configuration Software >
Download Configuration Software
2.
Plug the supplied Primex USB configuration cable into a USB port on your computer.
3.
Plug the configuration cable mini-USB connector into the bridge's USB mini port.
The bridge detects the connection to your computer and enters configuration mode. The LCD displays the letters Con and the
Config icon is displayed indicating the device is in configuration mode.
4.
Open the Primex Device Configuration software. Go to All Programs > Primex > Primex Device Configuration or from your
computer desktop, double-click on the Primex Device Configuration icon.
5.
From the Enter Password window, enter the factory default password (case sensitive) - Primex1
12