26 INSTALLATION, MAINTENANCE AND USER' MANUAL 540889_PUB_DATE_1_JUL_2011.DOC
Installation
Venting
WARNING
VAPOURS ESCAPE FROM THE MACHINE THROUGH THE AIR VENT OPENING!
SEE (FIG.8). DO NOT COVER!
Liquid soap connection
General : Always use liquid soap pumps with a flow rate that can bring the requested quantity in less
than 30sec.
Important : Start pumping immediately after the water valves are open. The incoming water dilutes the liquid
soap and brings it into the tub assembly.
Caution: The machines are produces in two versions:
Without liquid soap (standard version)
With liquid soap (according to the request)
Secure the location of the wiring and hoses in such a way that they can not be pinched, damaged
or rubbed. Before you start to use liquid soap, check with your liquid soap supplier whether the liquid soap is
harmless and inert to PP and PVC material in order to avoid a problem that manufacturer is not responsible
for.
The washer has provisions for connecting external dosing of liquid soaps. On the back side, a plastic hose
connection part is present, fig.10., pos.1. to connect the liquid soap hoses. Depending of the number of liquid
soap pumps that will be used, drill holes (max. 8) of Ø 8 mm / 0.315“ in the plastic hose connection part for
each pump.
On the plastic hose connection part is also a 3 nipples of Ø 12 mm / ½“. Use this nipple ONLY for entering
diluted soap. Drill with Ø 11.5 mm / 0.45“. By default, these nipples are closed. Drill only the ones that will be
used.
Take care that the drill particles are carefully removed so that they can not clog up the hoses and openings.
check that the hose connections are tight (check the clamps)! any leakage of chemicals may cause serious
body injuries as well as serious damage to the washer. if one of the nipples are open, close and secure the opening
with an appropriate cover.
!