FS Reader – User & Service manual – 00.010 19
Service
Replace battery
To avoid loss of data, make sure to do a final upload with the FS Reader.
After replacing the battery, fully charge the battery for the best performance.
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
1. Upload registrations.
To avoid loss of data, make sure to do a final upload with the FS Reader by
pushing the middle soft key. Wait until all registrations have been transferred
from the FS Reader (see section “Store Registrations”).
2. Replace the battery:
a. Open the FS Reader by unscrewing the four screws at the backside,
using a Torx T10 screwdriver.
b. Take out the old battery and position the new battery.
See section “Technical specifications” on page 21 for the correct type of
battery.
c. Close the FS Reader and fasten the four screws again.
3. Place the FS Reader in the FS Cradle.
The FS Reader will restart automatically. Fully charge the new battery for the
best performance.
Reset for usage at other location
1. Upload all registrations from the FS Reader.
2. Unlink the FS Reader in the FS Reader Software.
3. Enter the FS Reader Service menu, select the “Factory reset” option and confirm
by pressing the indicated ‘Yes’ key.
The FS Reader is now ready to move it to a different location and take it into operation in
accordance with the normal procedure for a new FS Reader.