9085754 PROCUT 30A Digi Plus Plasma Cutter V1.0
8 For technical questions call 1-800-665-8685
12. Do not point the plasma torch at any body part of yourself or at
anyone else.
13. Do not use a plasma cutting machine to thaw frozen pipes.
14. Insulate yourself from the work and the ground using dry insulation.
Make certain that the insulation is large enough to cover your full
area of physical contact.
15. Never dip the electrode in water for cooling.
16. When not welding, make certain that no part of the electrode circuit is
touching the workpiece or the ground. Accidental contact can cause
overheating and create a fire hazard.
17. Maintain good ventilation of the louvers on this equipment. Good
ventilation is of critical importance for the normal performance and
service life of this equipment.
18. Keep the plasma cutter out of direct sunlight.
FIRE AND EXPLOSION PRECAUTIONS
Arc welding can produce sparks, hot slag or spatter, molten metal drops
and hot metal parts that can start fires.
1. Clear the floor and walls of an area of all combustible and/or flammable
materials up to 39 ft (12 metres) away from the plasma cutting machine.
Hot debris ejected during welding can land at a considerable distance
away. Solid floors of concrete or masonry is the preferred
working surface.
1.1 Cover any combustible material with fire resistant covers or
shields, if it cannot be removed. The covering must be tight and
should not leave openings for sparks or ejected slag to enter.
1.2 Check both sides of a panel or wall for combustible material. Remove
the combustible material before welding.
2. A combustible floor should be protected with a fire-resistant
covering.
3. Seal cracks and openings to adjacent areas that a spark or slag can
enter. Seal any openings found with a fire-resistant cover. Shut doors
and windows that do not provide ventilation or erect protective
screens in front of them when possible.
4. Avoid welding near hydraulic lines or containers containing
flammable contents.