SAFETY
PRODUCT FEATURES
This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters
and can be operated with the ue damper closed. State and local codes in some areas prohibit
the use of vent-free heaters.
Install and use heater with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code, ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
LOCAL CODES
State of Massachusetts: The installation
must be made by a licensed plumber or
gas tter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
In the State of Massachusetts the gas
cock must be a T-handle type. The State
of Massachusetts requires that a exible
appliance connector cannot exceed three
feet in length.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shuto system. The
ODS/pilot shuts o the heater if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic
piezo control system. This system requires
AAA batteries (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner
on and off to maintain a desired room
temperature.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
propane or natural gas. The heater is shipped
from the factory ready for connecting to pro-
pane. The heater can easily be changed to
natural gas by having your qualied installer
follow the instructions on page 12 and the
markings on the heater.
10. Do not use heater if any part has been
under water. Immediately call a qualied
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
11. Turn o and unplug heater and let cool
before servicing. Only a qualied service
person should service and repair heater.
12. Operating heater above elevations of
4,500 feet could cause pilot outage.
13. Do not use this heater if any log is broken.
Do not operate heater if a log is chipped
(dime-size or larger).
14. To prevent performance problems, do not
use propane fuel tank of less than 100 lbs.
capacity.
15. Solid fuels should not be burned in
replace in which a vent-free log set is
installed. Do not use this heater to cook
food or burn paper or other objects.