PROLIGHTS - EclProfile CT+
03
T
45°
C
a
Max operating ambient temperature (Ta)
• Do not operate the xture if the ambient temperature (Ta) exceeds 45 °C (113 °F).
T
-20°
C
a
Minimum operating ambient temperature (Ta)
• Do not operate the xture if the ambient temperature (Ta) is below -20 °C (-4 °F).
Protection from burns and re
• The exterior of the xture becomes hot during use. Avoid contact by persons and
materials.
• Ensure that there is free and unobstructed airow around the xture.
• Keep ammable materials well away from the xture
• Do not expose the front glass to sunlight or any other strong light source from any an-
gle. Lenses can focus the sun’s rays inside the xture, creating a potential re hazard.
• Do not attempt to bypass thermostatic switches or fuses.
Indoor use
• This product is designed for indoor and dry environments.
• Do not use in wet location and do not expose the xture to rain or moisture.
• Never use the xture in places subject to vibrations or bumps.
• Make certain that no inammable liquids, water or metal objects enter the xture.
• Excessive dust, smoke uid, and particle build up degrades performance, causes
overheating and will damage the xture.
• Damages caused by inadequate cleaning or maintenance are not covered by the
product warranty.
T
50°
C
c
Temperature of the external surface
• The surface of the xture can reach up to 50 °C (122 °F) during operation. Avoid
contact with people and materials.
Maintenance
• Warning! Disconnect the xture from AC mains power and allow to cool for at least
10 minutes before handling.
• Only technicians who are authorized by PROLIGHTS or Authorised service partners
are permitted to open the xture.
• Users may carry out external cleaning, following the warnings and instructions pro-
vided, but any service operation not described in this manual must be referred to a
qualied service technician.
• Important! Excessive dust, smoke uid, and particle build up degrades performance,
causes overheating and will damage the xture. Damages caused by inadequate
cleaning or maintenance is not covered by the product warranty.
Photobiological safety
• This device emits potentially dangerous optical radiation and is identied in the cat-
egory of Risk Group 2 according to EN 62471.
Minimun
distance
Risk
Group 2
Risk
Group 1
0.2 m
0.7 ft
3.30 m
10.83 ft