Parameter PID GET SET
SUPPORTED_PARAMETERS 0x0050 x
DEVICE_INFO 0x0060 x x
DEVICE_MODEL_DESCRIPTION 0x0080 x
MANUFACTURER_LABEL 0x0081 x
DEVICE_LABEL 0x0082 x x
FACTORY_DEFAULTS 0x0090 x x
SOFTWARE_VERSION_LABEL 0x00c0 x
BOOT_SOFTWARE_VERSION_ID 0x00c1 x
BOOT_SOFTWARE_VERSION_LABEL 0x00c2 x
DMX_PERSONALITY 0x00e0 x x
DMX_PERSONALITY_DESCRIPTION 0x00e1 x
DMX_START_ADDRESS 0x00f0 x x
SENSOR_DEFINITION 0x0200 x
SENSOR_VALUE 0x0201 x
DEVICE_HOURS 0x0400 x
LAMP_HOURS 0x0401 x
LAMP_STRIKES 0x0402 x
DEVICE_POWER_CYCLES 0x0405 x
IDENTIFY_DEVICE 0x1000 x x
RESET_DEVICE 0x1001 x
PROLIGHTS - EclProfile CT+
16
10 - RDM FUNCTIONS
The product can communicate using RDM (Remote Device Management) protocol over a DMX512
Networks.
RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open
standard for DMX512 device conguration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting
existing non-RDM equipment. It allows a console or dedicated RDM controller to send commands to
and receive messages from specic xtures.
The PIDs in the following tables are supported in the product.