ID 6
Use the table below to solve minor problems.
Please follow steps below to download and install monitoring software:
Go to the website http://www.power-software-download.com
Click ViewPower software icon and then choose your required OS to download the software.
Follow the on-screen instructions to install the software.
When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.
1.
2.
3.
4.
7. Permasalahan
6. Software Download & Instalasi
If any abnormal situations occur that are not listed above, please call for service immediately.
Ganti baterai dengan jenis yang
sama.
Tekan saklar daya lagi untuk
menghidupkan UPS.
Masalah Kemungkinan Solusi
Tidak ada LED yang
menyala pada panel
depan.
Baterai lemah. Charge UPS minimal 6 jam.
Baterai rusak.
UPS belum dihidupkan.
Alarm secara terus
menerus berbunyi
ketika sumber listrik
normal.
UPS overload.
Lepaskan beberapa beban yang
terhubung ke UPS. Sebelum
dipasang kembali, harap pastikan
beban masih dapat diterima oleh
UPS yang sesuai pada spesifikas.
Ketika sumber listrik
terputus, waktu
back-up sangat
pendek.
UPS overload. Lepaskan beberapa beban critical.
Tegangan baterai sangat rendah. Charge UPS minimal 6 jam.
Baterai rusak. Mungkin
disebabkan karena suhu
ruangan yang tinggi, atau
operasi yang tidak layak pada
baterai.
Ganti baterai dengan jenis yang
sama.
Listrik normal tetapi
LED berkedip.
Kabel power longgar.
Hubungkan kembali kabel power
dengan benar.