Questions and Answers

  • T
    Thomas DunnAug 11, 2025
    What to do if Protemp PT-45-KFA-EU Heater has poor combustion and/or excess soot production?
    • T
      Tracy HarveyAug 11, 2025
      If your Protemp Heater is producing excessive soot or has poor combustion, there are several potential causes. First, check the air filter, and clean or replace it if it's dirty. Also, inspect the fuel filter and replace if needed. Ensure the fuel you are using is of good quality and free from contamination. Finally, verify that the BAR pressure is set correctly.
  • M
    Michael JohnsonAug 17, 2025
    What to do if my Protemp PT-45-KFA-EU fires but shuts off quickly and shows “E1”?
    • S
      Sharon MartinAug 17, 2025
      If your Protemp Heater starts but shuts down shortly after with a flickering lamp and an “E1” error, it could be due to several reasons. Start by adjusting the pump pressure. Then, clean or replace the air filter, fuel filter, and nozzle. Also, clean or replace the photocell and ensure it's properly positioned. If the issue persists, the photocell might be defective and need replacement. Check the wiring connections between the Main PCB and the Photocell. For models other than the 45-KFA, check the thermistor placement. Finally, consider replacing the temperature limit switch.
  • M
    michelle89Aug 25, 2025
    What to do if Protemp PT-45-KFA-EU won't operate and shows “E1” error?
    • A
      andrew52Aug 25, 2025
      If your Protemp Heater isn't operating, or the motor runs briefly, accompanied by a flickering lamp and an “E1” error, begin by ensuring the fuel tank has paraffin. Then, adjust the pump pressure. Clean or replace the spark plug, fuel filter, and nozzle. If there's moisture in the fuel or tank, rinse the tank with fresh paraffin. Inspect the electrical connections between the transformer and circuit board, and re-attach the ignitor wire to the spark plug if it's disconnected. If the issue continues, the ignitor might be defective and require replacement. Finally, adjust the rotor spacing.
  • R
    Robert HernandezAug 30, 2025
    What to do if Protemp PT-45-KFA-EU Heater does not turn on?
    • N
      Nancy MclaughlinAug 30, 2025
      If your Protemp Heater isn't turning on and the lamp is unlit, it could be due to a few reasons. First, the temperature limit sensor might have overheated; turn the power switch off and allow the heater to cool for 10 minutes before switching it back on. Ensure the heater is receiving electrical power by checking the power cord and extension cord connections, and testing the power supply. Also, check and replace the fuse if it is blown. Finally, inspect the electrical connection between the temperature limit sensor and the circuit board.
  • M
    Margaret HardySep 4, 2025
    What to do if Protemp PT-45-KFA-EU Heater lamp is flickering and shows “E3”?
    • K
      kwalkerSep 4, 2025
      If the lamp is flickering, and the LED display shows “E3”, replace the thermostat switch.