CONSUMER: READ AND SAVE THESE INSTRUCTIONS
SSRA-400
GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you need heater info; such as
an operating manual, labels, etcetera, contact the manufacturer.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
WITHOUT ADEQUATE VENTILATION. FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED
BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is
an unvented portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to “Ventilation” on Page 8.
DANGER
Users Manual &
Operating Instructions
®
Factory ID: 001
Model Numbers
PT-70-SS-EU / PT-70T-SS-EU / PT-125-OFR-EU
© 2017, Obelis S.A Registered Address:
Bd. Général Wahis, 53
1030 Brussels, Belgium
Question and Answer IconNeed help?

Do you have a question about the Protemp PT-70-SS-EU and is the answer not in the manual?

Summary

Safety Information

Fire, Burn, Inhalation, and Explosion Hazards

Warning about fire, burn, inhalation, and explosion hazards. Keep combustibles away, avoid volatile products.

Understand Safety and Operating Instructions

Crucial warning to read and understand all safety and operating instructions before use to prevent serious injury or death.

Avoid Operating with Excess Oil or Hot Chamber

Warnings against starting the heater when excess oil has accumulated or when the chamber is still hot.

Indoor Air Pollution and Carbon Monoxide Risk

Warning about indoor air pollution and carbon monoxide poisoning risk due to combustion products. Emphasizes ventilation.

Carbon Monoxide Poisoning May Lead to Death

Critical warning on carbon monoxide toxicity and fatal risks from inadequate ventilation, listing symptoms.

Electric Shock Risk

Warning about electric shock risks, specifying correct voltage, grounded outlets, and extension cord usage.

Burns, Fire, and Explosion Risks

Warning regarding burns, fire, and explosion risks. Prohibits specific fuels, hot refueling, and blocking airflow.

Caution: Hot During Operation

Cautionary statement that the heater is hot during operation and to keep children, animals, clothing, and combustibles away.

Specifications

Features

Assembly Instructions

Carry Handle Assembly

Instructions for attaching the carry handle to the heater using screws, referencing figures.

Operation

Fueling The Heater

Instructions and warnings for fueling the heater, specifying approved fuels and storage recommendations.

Ventilation Requirements

Guidance on ventilation requirements for safe operation, emphasizing fresh air openings to prevent CO poisoning.

Starting, Stopping, and Restarting Heater

Starting the Heater (Ignition)

Step-by-step instructions for starting the heater, including fuel filling and power connection.

Stopping the Heater (Cool Down)

Procedure for safely stopping the heater, including the mandatory cooling cycle before unplugging.

Restarting the Heater

Steps for restarting the heater after it has completed its cooling cycle.

Electrical Outlet (PT-70 T-SS-EU Only)

Specific information regarding the auxiliary electrical outlet on the PT-70T-SS-EU model.

Maintenance Schedule

Long Term Storage

Instructions for preparing the heater for long-term storage, including fuel removal and proper storage conditions.

General Service Advice

Advice to not tamper with the unit and to use experienced servicemen for adjustments or repairs.

Fuel Tank Maintenance

Maintenance for the fuel tank, recommending flushing every 200 hours.

Spark Plug Maintenance

Maintenance for the spark plug, including cleaning, re-gapping, or replacement every 600 hours.

Fan Blades Cleaning

Instructions for cleaning fan blades at least once per heating season to remove dust and dirt.

Pressure Adjustments

Guidance on adjusting fuel and air pressure for optimal operation and troubleshooting smoking or flame issues.

Nozzle Cleaning and Replacement

Instructions for cleaning or replacing nozzles at least once per heating season.

Photocell Cleaning

Instructions for cleaning the photocell lens at least once per heating season.

Filter Cleaning

Instructions for cleaning fuel and oil filters at least twice per heating season.

Troubleshooting Guide