Model #s: PT 45-KFA, PT 70T-KFA,
PT 125T-KFA, PT 175T-KFA, PT 215T-KFA
CONSUMER: Retain this manual for future reference.
Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19076 USA
Phone: 215-891-8460 Fax: 215-891-8461 Web: www.pinacleint.com Email: info@pinnacleint.com
Owners Manual and
Operating Instructions
Kerosene
Forced Air Heaters
IMPORTANT: Read and understand all of the directions in this manual before assembling,
starting, or servicing the heater. Improper use of this heater can cause serious injury. Keep this
manual for future reference.
GENERAL HAZARD WARNING:
Be sure to comply with the instructions and warnings provided with this heater, or death, seri-
ous bodily injury and property loss, damage from the hazards of fire, explosion, burn, asphyxia-
tion, and carbon monoxide poisoning can result.
Only persons who can follow and understand these instructions should use or service this
heater. If you need heater information such as an instruction manual, labels, etcetera, contact
the manufacturer.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
C US

Questions and Answers

  • A
    allenjohnsonAug 6, 2025
    What to do if my Protemp PT 70T-KFA fires then shuts down with an E1 error?
    • P
      patrick77Aug 6, 2025
      If your Protemp Heater starts but then shuts down, and the LED display shows “E1” with a flickering lamp, the possible causes include incorrect pump pressure, a dirty input, output, or lint filter, a dirty fuel filter, a dirty nozzle, a dirty or defective photocell, or a fuel valve issue. Try these steps: adjust the pump pressure, clean or replace the air filter, fuel filter, and nozzle. Also, clean or replace the photocell, adjust its position, or replace it if defective. Finally, check the wiring connections between the circuit board and photocell, and inspect the fuel valve.
  • S
    sandrakelleyAug 16, 2025
    What to do if Protemp PT 70T-KFA Heater fan not working?
    • A
      Alan MosesAug 17, 2025
      If the fan on your Protemp Heater does not operate when plugged in and the power switch is in the “ON” position, and the lamp is flickering or on, it could be due to the thermostat being set too low or a broken electrical connection between the circuit board and the motor. Try rotating the thermostat to a higher setting and inspect all electrical connections.
  • H
    Holly BanksAug 22, 2025
    What does E2 error mean on Protemp Heater?
    • G
      gina01Aug 22, 2025
      If the lamp is flickering and the LED display shows “E2” on your Protemp Heater, it indicates a problem with the room temperature sensor. This could be due to a disconnected sensor or a sensor failure. Try re-connecting the temperature sensor, or replacing it if necessary.
  • E
    Elizabeth DuranAug 27, 2025
    What does E3 error mean on Protemp Heater?
    • L
      Lydia RobinsonAug 27, 2025
      If the lamp is flickering and the LED display shows “E3” on your Protemp Heater, it means that the thermostat switch has failed. Replace the thermostat switch.
  • K
    kimberlychapmanAug 31, 2025
    How to fix a Protemp PT 70T-KFA that won't turn on?
    • T
      teresakeithAug 31, 2025
      If your Protemp Heater does not turn on and the lamp is not lit, it could be due to several reasons. The temperature limit sensor may have overheated, there might be no electrical power, or the fuse could be blown. Also, check the electrical connection between the temperature limit sensor and the circuit board. First, push the power switch to “OFF” and allow the heater to cool for 10 minutes, then push the power switch back to “ON”. Check the power cord and extension cord to ensure they are properly connected and test the power supply. Finally, check and replace the fuse if necessary.
  • D
    Debra StevensNov 10, 2025
    Why Protemp PT 70T-KFA Heater won't start and shows E1 error?
    • S
      susanolsonNov 10, 2025
      If your Protemp Heater won't operate, or the motor runs briefly, and the LED display shows “E1” with a flickering lamp, it could be due to several reasons. There might be no kerosene in the fuel tank, or the pump pressure could be incorrect. Other potential issues include a corroded spark plug, a dirty fuel filter or nozzle, or moisture in the fuel tank. Also, check the electrical connections between the transformer and circuit board, ensure the transformer wire is connected to the spark plug, and inspect the transformer and fuel valve for defects. Try these solutions: fill the tank with fresh kerosene, adjust the pump pressure, clean or replace the spark plug, fuel filter, and nozzle. Rinse out the fuel tank with clean kerosene, re-attach the transformer wire to the spark plug, and replac...

Summary

Owners Manual and Operating Instructions

Important Safety Notice

Read and understand all directions before assembly, starting, or servicing the heater.

General Hazard Warning

Comply with instructions and warnings to avoid death, serious injury, or property loss from hazards.

Covered Model Numbers

Lists the specific model numbers covered by this manual: PT 45-KFA through PT 215T-KFA.

Features

Heater Components Diagram (PT 45;70 T-KFA)

Diagram illustrating the various parts of the heater for PT 45/70T-KFA models.

Heater Components Diagram (PT 125 T;175 T;215 T-KFA)

Diagram illustrating the various parts of the heater for PT 125T/175T/215T-KFA models.

Specifications

Product Specifications Table

Detailed technical specifications for various Protemp heater models.

Product Dimensions

Visual representation of heater dimensions for different models.

Safety Information

Carbon Monoxide Poisoning Hazard

Details dangers of CO poisoning and symptoms of improper ventilation.

General Safety Precautions

Lists critical safety rules including fuel, placement, and operation.

Regional Safety Advisories

Specific warnings for California, Massachusetts, and New York City residents.

Theory of Operation

Fuel System Explanation

Describes how fuel is drawn, mixed with air, and atomized.

Ignition and Air Systems

Explains the quick-fire ignition and air circulation mechanisms.

Electrical System and Flame Sensor

Covers circuit protection and the function of the flame sensor.

Unpacking and Assembly

Parts Check for Assembly

Checklist of parts required for heater assembly, with model variations.

Frame Component Diagrams

Illustrations of frame components for different models.

Assembly Instructions

Handle and Cordwrap Assembly (PT 45;70 T-KFA)

Step-by-step instructions for attaching the handle and cordwrap.

Frame and Wheel Assembly (PT 125 T;175 T;215 T-KFA)

Detailed steps for assembling the frame, wheels, and handles.

Fuel, Ventilation, and Operation

Fueling Guidelines

Instructions for safe fueling, including fuel type and storage.

Ventilation Requirements

Specifies the fresh air opening requirements for safe operation.

Starting and Stopping the Heater

Step-by-step instructions for operating and shutting down the heater.

Maintenance

Electrical Outlet Safety

Warning regarding the electrical outlet's amperage limit and coverage.

Maintenance Schedule and Procedures

Routine maintenance tasks for filters, fuel tank, spark plug, and photocell.

Pump Pressure Adjustment

Guidance on adjusting pump pressure for optimal performance.

Long Term Storage

Drain Fuel Tank Procedure

Steps for draining the fuel tank for storage.

Storage Recommendations

Instructions for storing the heater safely and properly.

Trouble Shooting Guide

Common Heater Problems and Solutions

Lists common issues, their causes, and recommended solutions.

Wiring Diagrams

Electrical Schematics for Models

Wiring diagrams for PT 45-KFA, PT 70T-KFA, and PT 125/175/215T-KFA models.

Exploded Drawing Part Breakdown

Parts Identification Diagram

Visual breakdown of heater components with numbered parts.

Bill of Materials

Parts List by Key Number

Comprehensive list of parts with key numbers, descriptions, and part numbers.

Limited Warranty

Warranty Terms and Conditions

Details the warranty period, coverage, exclusions, and claims process.

Protemp PT 70T-KFA Specifications

General IconGeneral
Heating Capacity70, 000 BTU
Ignition TypeElectronic
Heat SettingsSingle
Safety FeaturesOverheat Shut-Off, Flame-Out Sensor
Heater TypeForced Air Kerosene Heater
Fuel TypeKerosene, Diesel, Fuel Oil
Coverage Area1, 750 sq. ft.
Run Time at Max OutputApproximately 10 hours on high setting