GENERAL HAZARD WARNING:
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion
that can cause property loss, bodily injury, or loss of life. Only persons who can follow and
understand these instructions should operate or service this heater. If you need heater info; such as
an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996.
DANGER
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES
WITHOUT ADEQUATE VENTILATION. FOR OUTDOOR USE. INDOOR USE
PERMITTED ONLY FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED
BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is
an unvented portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide
poisoning, bodily injury or death. Refer to “Ventilation” on Page 7.
DANGER
®
FACTORY ID: 001

Questions and Answers

  • B
    Brenda FernandezAug 18, 2025
    Why Protemp PT-175T-KFA has poor combustion and excess soot production?
    • R
      Rebecca GrayAug 18, 2025
      Poor combustion and excess soot production in your Protemp Heater may be due to: * Dirty input, output, or lint filter: Clean or replace the air or lint filter. * Dirty fuel filter: Clean or replace the fuel filter. * Poor quality of fuel: Flush the fuel tank and refuel the heater with good quality fuel. * Incorrect PSI: Ensure you are using the proper pressure. * Dirty nozzle: Clean or replace the nozzle.
  • N
    Nancy RobertsAug 23, 2025
    What to do if my Protemp PT-175T-KFA will not operate and shows error E1?
    • M
      Mary SchmidtAug 23, 2025
      If your Protemp Heater won't operate, the motor runs briefly, and the LED displays “E1”, consider these potential causes: * No kerosene in the fuel tank: Fill the tank with fresh kerosene. * Incorrect pump pressure: Adjust the pump pressure. * Corroded spark plug or incorrect plug gap: Clean or replace the spark plug. * Dirty fuel filter: Clean or replace the fuel filter. * Dirty nozzle: Clean or replace the nozzle. * Moisture in fuel tank: Rinse the fuel tank with clean, fresh kerosene. * Improper electrical connection between transformer and circuit board: Inspect all electrical connections. * Ignitor wire not connected to spark plug: Re-attach the ignitor wire to the spark plug. * Defective ignitor: Replace the ignitor. * Improper spacing with rotor: Adjust rotor.
  • R
    ruizrobertAug 26, 2025
    What to do if my Protemp Heater fan does not operate and shows error E1 or E2?
    • S
      Steven NielsenAug 26, 2025
      If the fan in your Protemp Heater does not operate when plugged in and the power switch is in the “ON” position, and the LED display shows “E1” or “E2”, check the following: * Thermostat setting: Rotate the thermostat to a higher setting. * Electrical connections: Inspect all electrical connections between the main PCB and the motor.
  • B
    Brandi HensonAug 27, 2025
    What to do if my Protemp Heater does not turn on?
    • G
      Gerald RodriguezAug 27, 2025
      If your Protemp Heater does not turn on and the lamp is not lit, consider the following: * Temperature limit sensor: Push the power switch to “OFF” and allow the heater to cool for 10 minutes, then restart the heater. * Electrical power: Check the power cords for proper connection and test the power supply. * Fuse: Check or replace the fuse. * Improper electrical connection: Inspect all electrical connections between the temperature limit sensor and the circuit board.
  • A
    Ann SharpAug 30, 2025
    What to do if Protemp PT-175T-KFA Heater doesn't operate and shows E1?
    • G
      garrettnancyAug 30, 2025
      If your Protemp Heater doesn't operate, the motor runs briefly, the lamp flickers, and the LED displays 'E1', here are some things to check: 1. Ensure the fuel tank has fresh kerosene. 2. Adjust the pump pressure if it's incorrect. 3. Clean or replace a corroded spark plug with an incorrect gap. 4. Clean or replace the fuel filter if it is dirty. 5. Clean or replace the nozzle if it is dirty. 6. Rinse the fuel tank with fresh, clean kerosene if there's moisture inside. 7. Inspect all electrical connections between the transformer and circuit board. 8. Re-attach the ignitor wire to the spark plug if it's disconnected. 9. Replace the ignitor if it is defective.
  • T
    torresbrianSep 1, 2025
    Why does my Protemp Heater shut off after igniting and shows E1?
    • T
      Terri AndrewsSep 1, 2025
      If your Protemp Heater ignites but the main PCB shuts off shortly after, displaying 'E1' and the lamp flickers, it could be due to several reasons: * Incorrect pump pressure, which requires adjustment. * A dirty input, output, or lint filter, which should be cleaned or replaced. * A dirty fuel filter, which should be cleaned or replaced. * A dirty nozzle, which should be cleaned or replaced. * A dirty photocell lens, which should be cleaned or replaced. * Improper installation or a defect in the photocell, requiring adjustment, or replacement. * Improper electrical connection between the main PCB and photocell; check wiring connections.
  • L
    Larry LongSep 3, 2025
    Why does my Protemp Heater shut off after a short time and show error code E1?
    • A
      Amanda ClarkeSep 3, 2025
      If your Protemp Heater ignites but the main PCB shuts off shortly after, and the LED display shows “E1”, here are some possible solutions: * Adjust the pump pressure. * Clean or replace the air, lint, or fuel filter. * Clean or replace the nozzle and photocell. * Adjust the photocell position or replace it if defective. * Check the wiring connections between the main PCB and photocell, and the placement of the thermister sensor. * Replace the temperature limit switch.
  • S
    Sarah AvilaSep 6, 2025
    What to do if my Protemp Heater will not operate and shows error code E1?
    • J
      Jamie BowmanSep 6, 2025
      If your Protemp Heater won't operate, or the motor runs briefly and the LED display shows “E1”, the following steps may help: 1. Refill the tank with fresh kerosene. 2. Adjust the pump pressure. 3. Clean or replace the spark plug, fuel filter, and nozzle. 4. Rinse the fuel tank with clean kerosene. 5. Inspect electrical connections. 6. Re-attach the ignitor wire to the spark plug, replace the ignitor if necessary, and adjust the rotor.
  • D
    Dr. Julian GomezSep 8, 2025
    How to fix poor combustion and soot production in Protemp Heater?
    • T
      Tony MontoyaSep 8, 2025
      If your Protemp Heater produces poor combustion or excess soot, consider these solutions: * Clean or replace the air, lint, and fuel filters. * Flush the fuel tank and refuel the heater with good quality fuel. * Ensure you are using the proper pressure. * Clean or replace the nozzle.
  • J
    Joshua BellSep 12, 2025
    Why is the fan not working on my Protemp PT-175T-KFA Heater and showing E1 or E2?
    • B
      brittanyaguilarSep 12, 2025
      If the fan in your Protemp Heater doesn't operate when plugged in and switched on, and the LED display shows “E1” or “E2”, try these: * Rotate the thermostat to a higher setting. * Inspect all electrical connections.

Summary

General Warnings and Usage Guidelines

Consumer Responsibility

Read and save all instructions before operating or servicing the heater.

Hazard Warnings and Use Restrictions

General hazards, not for residential use without ventilation, outdoor/construction use.

Detailed Safety Precautions

Fire, Burn, and Explosion Hazards

Keep combustibles away; avoid flammable products, ensure proper ventilation.

Environmental and Operational Safety

Indoor Air Pollution and CO Dangers

Carbon monoxide is toxic; ensure adequate ventilation to prevent poisoning.

Electrical Safety Precautions

Use grounded outlets/cords; unplug when not in use, avoid water exposure.

Fire and Explosion Prevention

Use correct fuel; never refuel hot heater; keep clear of flammables.

Clearance Requirements

Maintain specified clearances from combustibles for safe operation.

Assembly Instructions for Smaller Models

Assembly of Larger Models

Assembly Steps for Larger Models

Operation: Fueling and Ventilation

Fueling the Heater

Recommended fuel types, refueling safety, and storage guidelines.

Ventilation Requirements

Critical information on air pollution and carbon monoxide dangers.

Starting and Stopping the Heater

Troubleshooting Guide

Heater Ignites, Then Shuts Off

Possible causes and solutions for the heater shutting off shortly after ignition.

Heater Not Operating or Motor Short Run

Troubleshooting steps when the heater fails to start or motor runs briefly.

Heater Not Turning On

Troubleshooting steps when the heater does not power on at all.

Limited Warranty Information

Protemp PT-175T-KFA Specifications

General IconGeneral
ModelPT-175T-KFA
Fuel TypePropane
IgnitionElectronic
Heater TypePortable
Tank Capacity20 lbs
Safety Featurestip-over