Section Header
22
Model:
Floor Temp Limit: When the Floor Sensor has been enabled in feature 05, you can set a
floor limiting temperature between 20-45°C, this protects the floor from overheating.
(27°C is the default).
Note: ‘Air Sensor Only’ MUST NOT be used to control electric underfloor heating.
Floor Sensor or Both should be used.
Optimum Start: Optimum start will delay enabling of the heating system to the latest
possible moment avoiding unnecessary heating and ensure the building has reached its
desired temperature at the programmed time. The thermostat uses the rate of change
information to calculate how long the heating needs to raise the building temperature 1°C.
Rate of Change: Number of minutes to raise the temperature by 1°C.
Note: The user cannot change this feature and is for information only.
Programming Mode: The following program modes are available;
5/2 Day Programming – 4 levels for the weekdays and 4 different levels for
the weekend.
• 7 Day Programming – 4 levels for each day.
• 24 Hours – 4 levels over a 24 hour period.
• Non-Programmable – Basic up/down override temperature control.
Daylight Saving Time (DST): is where the thermostat sets the clocks forward one hour from
‘Standard Time during the summer months, and back again in autumn, in order to make
better use of natural daylight.
Program Type: You can select between 4 or 6 program/comfort levels.