Electric Floor Model
23
Section Header
Optional Settings - Feature Table
FEATURE DESCRIPTION SETTING
01
Temperature Format 00 = °C, 01 = °F (00 = Default)
02
Switching Differential 00 = 0.5°C, 01 = 1.0°C (Default) 02 = 2.0°C, 03 = 3.0°C
03
Output Delay 00 - 15 Minutes (00 = Default)
04
Up/Down Temperature Limit 00° - 10°C (00° = Default)
05
Sensor Selection 00 = Built in Sensor
01 = Floor Sensor Only
02 = Built in Sensor with Floor Sensor (Default)
06
Floor Temperature Limit
20°C – 45°C (28°C Default)
07
Optimum Start 00 = Disabled (Default) 01 = 1 Hour 02 = 2 Hours
03 = 3 Hours 04 = 4 Hours 05 = 5 Hours
08
Rate of Change
Information Only
09
Program Mode 00 = 5/2 01 = 7 Day 02 = 24 Hour
03 = None programmable
10
(DST) Daylight Saving 00 = Disabled (Default) 01 = Enabled
11 Program Type
00 = 4 Comfort Levels (Default)
01 = 6 Comfort Levels

Related product manuals