OPERATION
13
Only operate generator on a level surface.
Always connect the nut and ground terminal on the frame to an appropriate ground source.
WARNING!
Generator must be properly grounded to prevent electrocution.
How to Start Engine (See fig 8-14 )
Fig 9
Fig 12 Electric Start
Fig 14
CHOKERUN
CHOKE LEVER
CHOKERUN
CHOKE LEVER
W
AIT
5sec
Fig 11
SKIP THIS IF THE ENGINE IS
WARM OR HOT.
The ground terminal located on the back of the generator frame must always be used
to connect generator to a driven ground rod. Connect the ground terminal to the driven
ground rod with a No 8 AWG (American Wire Gauge) copper wire. The wire connects
to the terminal between the lock washer and nut. Tighten the nut securely to ensure
proper connection. Grounding the generator protects you from electric shock that
results from a build up of static electricity or undetected ground faults.
Fig 7
Grounding the Generator (See fig 7)
Fig 13 Recoil Start
START
Place generator on a level surface. All electrical loads MUST be disconnected from generator.
When using gasoline
Turn fuel valve to the “ON” position. (See fig 9
Slide the choke lever to the “Choke” position. (See fig 11) SKIP THIS IF THE ENGINE IS WARM OR HOT.
ON/OFF switch in the “Start” position for more than 15 seconds. Allow 1 minute between starting attempts.(See fig 12)
For manual start, turn the engine startO ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 13)
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 14)
When using LPG
Connect the gas pipe to the intake nozzle of regulator ; Open the valve of LPG bottle (See fig 8)
Slide the choke lever to the “Choke” position. (See fig 11) SKIP THIS IF THE ENGINE IS WARM OR HOT.
on キゥエ」ィ ィ・sエ。イエヤッウゥエゥッョッイ ッイ・ィ。 ・」ッョ、ウNャャッキ ゥョオエ・・エキ・・ョエ。イエゥョァエエ・ューエウN
For manual start, turn the engine startO ON/OFF switch to the “ON” position. Pull the recoil handle (starter
cord) slowly until resistance is felt, then pull rapidly. (See fig 13)
Let engine run for several seconds and then gradually, as engine warms up, slide the choke lever towards the “RUN”
position until the choke is fully slid to the “RUN” position. (See fig 14)
Fig 8
(See fig 12)
START

Table of Contents