1200 WATT GENERATOR
Generator Components
5
1. Handle
2. Fuel Cap
3. Fuel Tank
4. Fuel Shut-off
5. Recoil Starter
6. Engine On-Off Switch
7. Throttle Lever
8. Air Cleaner
9. Control Panel
10. Generator
11. Muffler
12. Cylinder
13. Spark Plug
1200 WATT GENERATOR
6
STARTING THE ENGINE
1. Disconnect all electric appliances from generator before starting.
2. Turn fuel shut-off lever to “ON”.
3. Move Choke lever all the way to the left.
4. Turn engine switch to “ON” position.
5. Pull recoil starter cord slowly until engaged,then pull briskly to start.
6. Once engine has started,move choke lever all the way back to the right.
CONNECTING ELECTRICAL APPLIANCES
Always allow engine to warm up before connecting any electrical load to the generator.
STOPPING ENGINE
1. Turn off all appliances,the disconnect them from the generator.
2. Turn engine Switch to “STOP” position.
3. Turn fuel shut-off lever to “OFF”.
4. Allow engine to cool before attempting to move the generator or to refuel.
RESETTING BREAKER BUTTONS
If reset rips,disconnect all external electrical appliances before pushing the reset button.
After reconnecting the external electrical appliance, if reset continues to trip that indicates
that the electrical lead connected to the generator from one or more of the appliances may
have a short circuit. In that event, discontinue use of that item until it has been checked
and/or repaired by a qualified technician.
PERIODIC MAINTENANCE
Service intervals
Clean air filter after every 150 hours of run time.(If use inf very dusty conditions,clean air
filter after every 10 hours of run time)
1. Remove foam filter and wash in mild detergent or dish washing liquid
2. Rinse thoroughly,than squeeze out excess water.
3. Allow to thoroughly dry at room temperature.
4. Pour a small amount of gasoline in filter element,then squeeze out any excess gasoline.
5. Replace filter.
Clean spark plug every 50 hours of run time.
1. Remove spark plug and clean electrode with wire brush.
2. Reset gap to .028-.031 in.(.7-.8mm)