9
Step 14 – Reconnect Batteries
Replace the bolt on the positive terminal - red cable.
Replace the bolt on the negative terminal - black cable -with the 11 mm jaw spanner.
Replace the terminal cover from the battery terminals. See Fig. 6.
Step 15 – Replace Battery Tray
Place the batteries back into the tray and secure using the two straps.
Replace the battery tray underneath the wheelchair as shown in Fig.5
Replace the two xings into the bottom of the battery tray to hold it in place, Fig. 4.
Step 16 – Replace Actuator
Replace the retainer with a slotted screwdriver and insert the bolt as shown in Fig.3.
Step 17 – Replace Cover
Replace the thumb screws securing the front cover to the wheelchair, shown in Fig 2.
Step 18 -Replace the Leg Rests
Adjust the centrally tted leg rest back to the optimum position for the user.
Attach the side mounted leg rest, if these were removed, as shown in Fig.1.