Step 14 – Reconnect Batteries
Replace the bolt on the positive terminal - red cable.
Replace the bolt on the negative terminal - black cable -with the 11 mm jaw spanner.
Replace the terminal cover from the battery terminals. See Fig. 6.
Step 15 – Replace Battery Tray
Place the batteries back into the tray and secure using the two straps.
Replace the battery tray underneath the wheelchair as shown in Fig.5
Replace the two xings into the bottom of the battery tray to hold it in place, Fig. 4.
Step 16 – Replace Actuator
Replace the retainer with a slotted screwdriver and insert the bolt as shown in Fig.3.
Step 17 – Replace Cover
Replace the thumb screws securing the front cover to the wheelchair, shown in Fig 2.
Step 18 -Replace the Leg Rests
Adjust the centrally tted leg rest back to the optimum position for the user.
Attach the side mounted leg rest, if these were removed, as shown in Fig.1.