12 7014-285C August 1, 2018
CB1200 Pellet Insert
Mark area of
floor to cut
Starter hole
F. Installation into a Factory-Built Fireplace
The following modications are permissible:
• Removal of damper or locked in open position
• Removal of smoke shelf or bae
• Removal of ember catches
• Removal of re grate
• Removal of view screen/curtain
• Removal of doors
• Removal of factory-built replace oor
• External trim pieces which do not aect the operation
of the replace may be removed providing they can be
stored on or within the replace for reassembly if the
insert is removed.
• The permanent metal warning label provided must be
attached to the back of the replace, with screws or
nails, stating that the replace may have been altered
to accommodate the insert, and must be returned to
original condition for use as a conventional replace.
Figure 12.1
Figure 12.2
Figure 12.3
250-2061
THIS FIREPLACE MAY HAVE BEEN ALTERED
TO ACCOMMODATE AN INSERT. IT MUST BE
RETURNED TO ITS ORIGINAL CONDITION
BEFORE USE AS A SOLID FUEL BURNING
FIREPLACE.
250-2061
Heath & Home Technologies
250-2061
5.5 in. width x 2 in. height
NON. ANOD. ALUM BLACK LETTERS ON SILVER
with 1/8 in. holes on both sides.
Black letters
Figure 12.1
• If the hearth extension is lower than the replace
opening, the portion of the insert extending onto the
hearth must be supported.
• Manufacturer designed adjustable support kit can be
ordered from your dealer.
The following is only one example as there are many
dierent models of factory-built replaces.
Keep sharp edge of
metal floor away from
power cord
Figure 12.4
Place the insert into the factory-built rebox. Ensure that
the power cord can not be damaged by the sharp metal
edge. You may need to cut out a notch to accommodate
the cord.
Using a saws-all, cut out the oor.
Measure and mark the metal oor for cutting. With a drill,
make a starter hole in each corner.
NOTE: This example is for reference only. Any
modications must not compromise the structural
integrity or reduce the protection for combustible
materials.
NOTE: Refer to chimney liner manufacturer for
recommendations on supporting the liner.
Installation into replaces without a permit will
void the listing.
• The rebrick (refractory), glass doors, screen rails,
screen mesh and log grates can be removed from a
factory-built rebox in order to gain minimum insert
opening requirements.
• Any smoke shelves, shields and baes may be
removed from a factory-built rebox if attached with
mechanical fasteners.
• The metal oor of the factory-built rebox may be
removed to facilitate the installation of the insert only
when a 1 inch (25mm) airspace is provided between
the insert and the oor of outer wrap.