8 7080-163D August 3, 2018
MT. VERNON E2-C
Model Mt. Vernon Pellet Stove E2
Laboratory OMNI Test Laboratories, Inc.
Report No. 061-S-83-2
Type
Solid Fuel Room Heater, Pellet Fuel
Burning Type
Standard
ASTM E1509-12, ULC S627-00 and
(UM) 84-HUD, Mobile Home Approved.
FCC
Complies with Part 15 of FCC Rules.
Operation is subject to the following two
conditions: (1) this device may not cause
harmful interference, and (2) this device
must accept any interference received,
including interference that may cause
undesired operation.
This pellet appliance needs periodic inspection and repair for proper operation. It is against federal regulations to operate
this pellet appliance in a manner inconsistent with the operating instructions in the owner’s manual.
The Quadra-Fire Mt. Vernon E2 Pellet Appliance meets the U.S. ENVIRONMENTAL PROTECTION AGENCY Certied
to comply with 2020 particulate emission standards at 0.74 G/HR EPA CFR subpart AAA, using ASTM E2779-10, ASTM
2515-11 Method- Pellet Appliance sections, CSA B415.1-10.
Emissions Report
Number:
0061PS094E
EPA Certication #: 98-17
EPA Certied Emissions: 0.74 g/hr
*LHV Tested Efciency: 83.2%
**HHV Tested Efciency: 77.9%
***EPA BTU Output: 12,682 - 39,428 / HR
****BTU Input: 16,396 - 50,775 / HR
Vent Size: 3 or 4, “L” or “PL”
Hopper Capacity: 80 lbs.
Fuel Wood Pellets
* Weighted average LHV efciency using data collected
during EPA emissions test.
**Weighted average HHV efciency using data collected
during EPA emissions test.
***A range of BTU outputs based on HHV and the burn
rates from the low and high EPA tests.
****Based on the maximum feed rate per hour multiplied
by approximately 8600 BTU’s which is the average BTU’s
from a pound of pellets.
1 Listing and Code Approvals
A. Appliance Certication
NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the ASTM
E1059-12, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482.
B. BTU & Efciency Specications
f i r e - p a r t s . c o m