MT. VERNON AE INSERT
E. Mobile Home Approved
This appliance is approved for mobile home
installations when not installed in a sleeping room and
when an outside combustion air inlet is provided.
The structural integrity of the mobile home oor, ceiling,
and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home and use only Listed pellet vent
Class “L” or “PL” connector pipe.
Outside Air Kit, part OAK-3 must be installed in a
mobile home installation.
D. Electrical Rating
115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualied
installer, service agency or your dealer.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be voided
by, the following actions:
Installation and use of any damaged appliance.
Modication of the appliance.
Installation other than as instructed by Hearth & Home
Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all
components.
Operating appliance without legs attached (if supplied
with appliance).
Do NOT Over re - If appliance or chimney connector
glows, you are over ring.
Any such action that may cause a re hazard.
NOTE: Hearth & Home Technologies, manufacturer
of this appliance, reserves the right to alter its
products, their specications and/or price without
notice.
F. Sleeping Room
G. California - Prop65
WARNING
This product and the fuels used to operate this product (wood), and
the products of combustion of such fuels, can expose you to
chemicals including carbon black, which is known to the State of
California to cause cancer, and carbon monoxide, which is known to
the State of California to cause birth defects or other reproductive
harm. For more information go to: WWW.P65Warnings.ca.gov
When installed in a sleeping room it is recommended that
3ft of vertical be installed prior to horizontally exiting the
room and a smoke/CO alarm be installed in the bedroom.
The size of the room must be at least 50ft³ per 1,000 Btu/
hr stove input, if the stove exceeds the room size, out air
must be installed
C. Glass Specications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.