EasyManua.ls Logo

Quantum DXi4700

Quantum DXi4700
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cabling the System
Quantum DXi4700 Capacity Upgrade Guide 40
Node JBOD 1 JBOD 2 JBOD 3
SAS port 2
(right)
Secondary SAS In port 1
(bottom)
Primary SAS port 2 (top) Primary SAS port 1 (top)
Secondary SAS port 2
(bottom)
Secondary SAS port 1
(bottom)
Primary SAS port 2 (top) Primary SAS port 1 (top)
Secondary SAS port 2
(bottom)
Secondary SAS port 1
(bottom)
2. Connect up to three CAT5 Ethernet cables to the 1 GbE ports (1, 2, and 3) (see Figure 32 on page 42).
3. If the DXi4700 is configured with an optional additional Ethernet adapter (10 GbE or 10 GBase-T),
connect the appropriate cable type:
l Dual 10 GbE (SFP+) Option (DXi4700 G1) - Connect up to two 10 GbE cables (optical or Twinax)
to the optional 10 GbE ports (4 and 5) (see Figure 32 on page 42).
l Dual 10 GbE (SFP+) Option (DXi4700 G2) - Connect up to two 10 GbE cables (optical or Twinax)
to the optional 10 GbE ports (4 and 5) (see Figure 33 on page 43).
l Dual 10 GBase-T Option - Connect up to two CAT6 Ethernet cables to the optional 10GBase-T
ports (4 and 5) (see Figure 34 on page 43).
Caution: CAT6 Ethernet cables can be easily damaged when tightened with plastic zip ties. Use
hook and loop cable straps instead.
4. (VTL and Multi-Protocol configurations only) Connect Fibre Channel cables to each Fibre Channel port
in slot 3 (see Figure 35 on page 43). Fibre Channel ports 0 and 1 are used for virtual tape library (VTL)
host connection.
5. (Multi-protocol configurations only) Connect Fibre Channel cables to each Fibre Channel port in slot 2
(see Figure 35 on page 43). Fibre Channel ports 2 and 3 are used for path to tape (PTT) connections.
6. Connect each power supply to a primary and secondary AC power source using the provided power
cables (see Figure 36 on page 44). Use the attached straps to secure the power cords to the chassis.
Note: Quantum recommends connecting each power cord to a separate AC circuit to ensure
system availability in case of a power failure. Power supplies should be checked periodically for
audible and LED warnings

Other manuals for Quantum DXi4700

Related product manuals