98 MIBs Implemented
STATUS current
DESCRIPTION "Device serial number as reported in SCSI Inquiry
command."
::= { physicalDriveEntry 2 }
phDriveModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device Model as would be reported in a SCSI Inquiry
command."
::= { physicalDriveEntry 3 }
phDriveVendor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device Vendor as would be reported in a SCSI Inquiry
command."
::= { physicalDriveEntry 4 }
phDriveType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Drive generation type."
::= { physicalDriveEntry 5 }
phDriveLocation OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Location of the Drive in the Library"
::= { physicalDriveEntry 6 }
phDriveFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only

Table of Contents

Other manuals for Quantum Scalar i500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i500 and is the answer not in the manual?

Quantum Scalar i500 Specifications

General IconGeneral
Form FactorRack-mountable
Product TypeTape Library
WeightVaries by configuration
Power ConsumptionVaries by configuration
Drive SupportLTO-8, LTO-7, LTO-6
ManagementWeb-based remote management
Drive TypeLTO Ultrium
Supported MediaLTO-5, LTO-6, LTO-7, LTO-8
Operating Temperature10°C to 35°C
Humidity20% to 80% (non-condensing)
InterfaceSAS

Related product manuals