EasyManuals Logo

Quectel BG96 TCP/IP User Manual

Quectel BG96 TCP/IP
53 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
LPWA Module Series
BG96 TCP/IP Application Note
BG96_TCP/IP_Application_Note 13 / 52
Parameter
2.2.3. AT+QIDEACT Deactivate a PDP Context
The Write Command deactivates a specific context and close all TCP/IP connections set up in this context.
Depending on the network, it may take at most 40 seconds to return OK or ERROR after executing
AT+QIDEACT. Before the response is returned, other AT commands cannot be executed.
If there is any error:
ERROR
Maximum Response Time
150 s, determined by network.
Characteristics
/
<contextID> Integer type. Context ID. Range: 1–16.
<context_state> Integer type. Context state.
0 Deactivated
1 Activated
<context_type> Integer type. Protocol type.
1 IPv4
2 IPv6
<IP_address> String type. The local IP address after the context is activated.
AT+QIDEACT Deactivate a PDP Context
Test Command
AT+QIDEACT=?
Response
+QIDEACT: (range of supported <contextID>s)
OK
Write Command
AT+QIDEACT=<contextID>
Response
OK
If there is any error:
ERROR
Maximum Response Time
40 s, determined by network.
Characteristics
/