GSM/GPRS/GNSS Module Series
MC60 Series Hardware Design
MC60_Series_Hardware_Design Confidential / Released 91 / 114
1.
1)
Power control level PCL 5.
2.
2)
Power control level PCL 0.
3.
3)
Under the EGSM900 spectrum, the maximum power of 1Rx and 4Tx is reduced.
Table 43: Power Supply Ratings of GNSS part
Parameter
Description
Conditions
Min.
Typ.
Max.
Unit
GNSS_
VCC
Supply voltage
Voltage must stay
within the min/max
values, including
voltage drop, ripple,
and spikes.
2.8
3.3
4.3
V
I
VCCP
1)
Peak supply current
VCC=3.3V
150
mA
VRTC
Backup domain voltage
supply
1.5
2.8
3.3
V
Sleep mode
AT+CFUN=4
IDLE mode
Sleep mode
0.68
13
0.73
mA
mA
mA
TALK mode
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
208/209
142/146
mA
mA
DATA mode, GPRS (3Rx, 2Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
359/360
232/250
mA
mA
DATA mode, GPRS (2 Rx, 3Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
431/413
311/339
mA
mA
DATA mode, GPRS (4 Rx, 1Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
215/153
153/162
mA
mA
DATA mode, GPRS (1Rx, 4Tx)
GSM850/EGSM900
1)
DCS1800/PCS1900
2)
499/469
3)
392/427
mA
mA
Peak supply
current (during
transmission
slot)
Maximum power control level
on GSM850 and EGSM900.
1.6
2
A
NOTES
Quectel
Confidential

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel MC60 Series and is the answer not in the manual?

Quectel MC60 Series Specifications

General IconGeneral
BrandQuectel
ModelMC60 Series
CategoryControl Unit
LanguageEnglish

Related product manuals