. Parameter setting and operation
16
“Cylinder Sensor interface”: Set the cylinder sensor parameter as “YES” or “NO” by pressing button
Z”or Z”.
If set as YES”: it can use the sensor to judge whether the air cylinder arrives at the special position or not.
If set as NO”: it doesn’t use the sensor and ignore the air cylinder whether it arrives at the special position.
Input4 is the inputting port of cylinder sensor.
When set “Input4:0”, namely, the low electrical level is effective: if Input4 is 0, the air cylinder arrives at the
special position.
When set “Input4:1”, namely, the high electrical level is effective: if Input4 is 1, the air cylinder arrives at the
special position.
“Start Key Work”: when pressing START”key, it feeds or not. It can
set YES”or “NO”by pressing button Z”or
Z”.
If set as YES”, it starts to feed after pressing “START” key during work.
“Foot key”: pause or not when triggering FOOT” key. It can set
“YES”or “NO”by pressing buttonZ”or “Z”.
If set as “YES”, it can pause the processing after triggering FOOT”
key.
If set as NO”, it
cannot
pause the
processing after triggering FOOT
key.
Press “ENT
Press “ENT
Z-axis maximal range
Set the ports Input1, Input2, Input3, Input4” as 1 (high electrical level) or 0(low electrical
level).
Press button “Z”or “Z” to set effective level as 1or 0.
For example: set input3 as effective level and it is connecting with a material detection
sensor, the unit starts to solder when detecting a workpiece, and it doesn’t solder when not
Press “ENT
Press “ENT” button