EasyManua.ls Logo

Quicksilver 855WE - Page 75

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Quicksilver 855WE — Electrical Systems
63
Do not allow shore power cable end to hang in water. An
electrical eld can result which can cause injury or death to
nearby swimmers.
To minimize shock and re hazards turn o cra’s shore
power connecon switch before connecng or
disconnecng shore power cable, connect shore power
cable to cra’s inlet before connecng to shore power
source, disconnect shore power cable at shore power rst,
and close shore power inlet cover ghtly.
AC Panel
Voltmeter
Reverse polarity indicator
Main breaker switch — 16 Amp
Main test buon
Baery charger breaker switch — 10 Amp
Outlets breaker switch — 7 Amp
Water heater breaker switch — 10 Amp
Microwave breaker switch — 6 Amp
Air condioner breaker switch — 16 Amp
Main breaker switch — 32 Amp
Air condioner #1 breaker switch — 20 Amp
Air condioner #2 breaker switch — 10 Amp
Air condioner pump breaker switch — 5 Amp
16 Amp Shore Power
32 Amp Shore Power

Table of Contents

Related product manuals