Quicksilver 855WE — Electrical Systems
63
Do not allow shore power cable end to hang in water. An
electrical eld can result which can cause injury or death to
nearby swimmers.
To minimize shock and re hazards turn o cra’s shore
power connecon switch before connecng or
disconnecng shore power cable, connect shore power
cable to cra’s inlet before connecng to shore power
source, disconnect shore power cable at shore power rst,
and close shore power inlet cover ghtly.
AC Panel
Voltmeter
Reverse polarity indicator
Main breaker switch — 16 Amp
Main test buon
Baery charger breaker switch — 10 Amp
Outlets breaker switch — 7 Amp
Water heater breaker switch — 10 Amp
Microwave breaker switch — 6 Amp
Air condioner breaker switch — 16 Amp
Main breaker switch — 32 Amp
Air condioner #1 breaker switch — 20 Amp
Air condioner #2 breaker switch — 10 Amp
Air condioner pump breaker switch — 5 Amp
16 Amp Shore Power
32 Amp Shore Power