Section IV - Operation
Quincy Compressor 19
Introduction).
On 3-phase units, check the rotation direction of drive motor. For this purpose, a
sheet with start-up instructions is tted to the outlet grating. When the rotation
direction is correct, the paper will be blown upwards. If the direction is wrong,
stop the compressor immediately and reverse two incoming electric lines.
A compressor equipped with a phase sequence relay will not start if the phase
sequence is wrong. In that case, reverse two incoming electric lines to solve the
issue.