Section V - Preventive maintenance
22 Quincy Compressor
• Preventive maintenance schedule
• Service kits
• Disposal of used material
Preventive maintenance schedule
CAUTION!
Before carrying out any maintenance, repair work or adjustments, proceed as follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Close the air outlet valve.
• Depressurize the compressor by opening the manual drain valve(s).
The operator must apply all relevant Safety precautions during maintenance or repair.
Warranty - Product Liability
Useonlyauthorizedparts.
AnydamageormalfunctioncausedbybadmaintenanceisnotcoveredbyWarrantyor
ProductLiability.
General
Whenservicing,replaceallremovedgaskets,O-ringsandwashers.
Intervals
ThelocalCustomerCentremayoverrulethespeciedmaintenanceschedule,especially
theserviceintervals,dependingontheenvironmentalandworkingconditionsofthe
compressor.
NOTICE!
The longer interval checks and actions must also include the shorter interval
checks.
Preventive maintenance schedule
Period
(note 1)
Running
hours
(note 1)
Operation
Daily - •Checkreadingsonthedisplay.
•Compressorswithintegratedairreceiverand/orcompressors
withintegratedrefrigerantdryer:
Checkifcondensateisdischargedregularly.
•Receivermountedcompressors:
Drainthecondensatemanuallyattheendoftheday.
•Compressorswithintegrateddryer:
Checkthedewpoint.
Every3
months
(note 2)
500
Inspecttheairinletlter(s)(AF).
Inspectthepreltermatsonthecoolingairintakeopenings(if
fitted).
Checkforcleannessanddamage.Cleanifdirty,replaceif
damaged.
Cleanthecompressorandchecktheaircooler.Ifnecessary,
clean by air jet.