Instruction book
58 9829 3199 74
In case of emergency, press the emergency stop button (S3) to stop the compressor
immediately.
Use the emergency stop button only in case of emergency!
5.6 Taking out of operation
Procedure
At the end of the service life of the compressor, proceed as follows:
1.
Stop the compressor and close the air outlet valve.
2. Switch off the voltage and disconnect the compressor from the mains.
3. Shut off and depressurize the part of the air net which is connected to the outlet valve.
Disconnect the compressor air outlet pipe from the air net.
4. Drain the water and condensate circuits.
5. Disconnect the condensate piping.
5.5 Stopping
Control panel
1. Press the test button on top of all electronic drains to discharge the condensate.
2. Press the stop button (6) of the Q-Control Touch: the compressor will stop and the sign for
automatic operation (4) will go out.
3. Close the air outlet valve (customer's installation).
4. Open the manual condensate drains.