Instruction book
9829 3199 74 65
Step Action
5 Fill the compressor sump with oil as specified in Oil specifications. The level should be
between the 2 lines on the sight-glass (SG). Reinstall the filler plug.
6 Switch on the voltage. Unlock the emergency stop button.
7 Run the compressor for a few minutes. Stop the compressor. If necessary, top up the
compressor sump with oil between the 2 lines on the sight-glass (SG).
8 After carrying out the maintenance operations of the related service plan, the service
warning must be reset. See also Service Menu.
7.3 Motor greasing
Fan motor of QOFT compressors
The bearings of the fan motor are greased for life. Contact your Customer Centre for the
replacement interval of the motor bearings.
Compressor drive motor (M1)
QOFT
Recommended grease: Contact Quincy Customer Centre.
Do not mix greases of different types.
7.4 Safety valves
Testing
The safety valves can be tested on a separate compressed air line. If the valves do not open at
the pressure specified in Settings of safety valves, consult Quincy.
• Never run the compressor without safety valves.
• No adjustments are allowed.